欢迎光临上海嗨润系统控制有限公司官网!

联系我们 收藏本站

全国免费咨询电话 021-63526338

热门关键词搜索:

German Standard 您当前所在位置: 主页> > English > Product Center > Industrial Cables > German Standard >

N2XH/ N2XCH

文章来源:http://www.trcables.com/   作者:上海嗨润   发布时间::2018-01-17 10:09   浏览次数:

返回:German Standard

Application and Description

N2XH power cables with enhanced resistance to fire are used mostly in areas where harm to human life or material must be prevented in case of fire such as industrial and public buildings, hotels, subway systems, hospitals etc. These cables are suitable for dry and wet environments as well as for outer application but are not suitable for direct burial into earth or water.

Standard and Approval

VDE 0276 part 604, VDE 0482-266-2, DIN EN 60332-3 / EN50266-2

Cable Construction

Solid or stranded plain copper conductor
to DIN VDE 0295 cl. 1, cl. 2, BS 6360 cl. 1, cl. 2 and IEC 60228 cl 1, cl. 2
XLPE insulation type 2XI1, to HD 604 S1
Color coded to DIN VDE 0293-308
Green-yellow ground conductor (3 conductors and above)
Special LSOH filler
For N2XCH version with concentric conductor:
plain round copper wires and one or two transverse counter helix of copper tapes
Thermoplastic polyolefin compound outer jacket type HM4, to HD 604 S1

N2XH/ N2XCHN2XH/ N2XCH

N2XH

Technical Characteristics

Working voltage: 600/1000 volts
Test voltage: 4000 volts
Minimum bending radius: 12 x Ø
Flexing temperature: +5º C to +50º C
Fixed installation temperature: - 40º C to +90º C
Short circuit temperature: +250º C
Flame retardant: VDE 0482 part 266-2, DIN EN 50266-2 / IEC 60332-3
Low corrosiveness of combustion gases to DIN VDE 0482 part 267/ EN 50267-2-2/IEC 60754-2
Halogen-free to DIN VDE 0482 part 267 /EN 50267-2-1/IEC 60754-1
Smoke density to DIN VDE 0482 part 268/HD 606/BS 7622 PT1,PT2/EN 50268-1,-2/IEC 61034-1,-2
Insulation resistance: >20 MΩ x km

N2XCH

Cable Parameter

N2XH

AWG NO. OF CORES X 
NOMINAL CROSS 
SECTIONAL AREA 
# X MM²
CONDUCTOR
TYPE
INSULATION THICKNESS MM NOMINAL 
OVERALL DIAMETER MM
COPPER WEIGHT KG / KM CABLE WEIGHT KG / KM
12 1x4 re 0.7 7.5 38 140
10 1x6 re 0.7 8.0 58 160
8 1x10 re 0.7 8.8 96 210
6 1x16 rm 0.7 9.7 154 270
4 1x25 rm 0.9 10.6 240 380
2 1x35 rm 0.9 12.7 336 490
1 1x50 rm 1.0 14.1 480 620
2/0 1x70 rm 1.1 16.0 672 830
3/0 1x95 rm 1.1 17.9 912 1200
4/0 1x120 rm 1.2 19.5 1152 1500
300mcm 1x150 rm 1.4 21.6 1440 1700
350mcm 1x185 rm 1.6 23.8 1776 2200
500mcm 1x240 rm 1.7 25.3 2304 2750
750mcm 1x300 rm 1.8 29.0 2880 3300
- 1x400 rm 2.0 37.0 3840 4420
- 1x500 rm 2.2 40.0 4800 5460
16 2x1.5 re 0.7 11.1 29 180
14 2x2.5 re 0.7 11.9 48 210
12 2x4 re 0.7 12.7 77 270
10 2x6 re 0.7 13.7 115 340
8 2x10 re 0.7 15.3 192 450
6 2x16 rm 0.7 17.3 307 600
4 2x25 rm 0.9 21.1 480 980
16 3x1.5 re 0.7 11.5 43 179
14 3x2.5 re 0.7 12.4 72 225
12 3x4 re 0.7 13.3 115 291
10 3x6 re 0.7 14.4 173 371
8 3x10 re 0.7 16.1 288 523
6 3x16 rm 0.7 18.2 461 773
4 3x25 rm 0.9 22.3 720 1200
2 3x35 rm 0.9 24.9 1008 1600
1 3x50 rm 1.0 26.0 1440 1800
16 4x1.5 re 0.7 12.2 58 208
14 4x2.5 re 0.7 13.2 96 265
12 4x4 re 0.7 14.2 154 352
10 4x6 re 0.7 15.4 230 454
8 4x10 re 0.7 17.5 384 647
6 4x16 rm 0.7 19.7 614 964
4 4x25 rm 0.9 24.5 960 1446
上一篇:NYY-J / NYY-O
下一篇:没有了